Home Services Medium-Voltage (MV) Systems

Featured Service

Medium-Voltage (MV) Systems

An MV switchgear project starts with a site survey; the dimensions of the existing switchyard and brand compatibility determine which cell type gets selected.

The right cell starts with the right measurement

During the survey, cell width, ceiling height and cable entry direction are recorded; these measurements determine the connection layout of the metal-enclosed cell. If an additional cell is being added to an existing switchyard, compatibility with the busbar system is checked separately.

Medium-Voltage (MV) Systems
Medium-Voltage (MV) Systems

In a circuit breaker cell, fault-clearing time stays in the 60-80 millisecond range, roughly ten times faster than a human reflex.

What's Included

  • MV switchgear site survey and technical compatibility check
  • Supply of circuit breaker, disconnector and load-break switch cells
  • Busbar system and cable termination installation
  • Protection relay parameterization
  • Insulation resistance and function tests
  • Integration of additional cells into an existing switchyard
  • Commissioning and test report

Circuit breaker cell

Used on feeder lines that require high fault-breaking capacity; busbar cross-section is sized to the short-circuit current.

Load-break switch cell

Offers a more economical solution on transformer protection lines; it switches load on and off rather than breaking fault current.

Standards We Apply

TS EN 62271 MV switchgear and control gear
IEC 60255 Protection relay and measurement

Frequently Asked Questions

Can a new cell be added to an existing MV switchgear?
If the busbar system and brand are compatible, an additional cell can be integrated into the existing switchyard; if not, we offer an alternative connection solution.
How long do the tests inside the cell take?
Insulation resistance and function tests are usually completed within a day, with the results report delivered the same day.
What's the difference between a load-break switch cell and a circuit breaker cell?
Circuit breaker cells can clear high-current faults, while load-break switch cells are mainly used as an economical option on transformer protection lines.
Do you set the protection relay parameters yourselves?
Yes, our team calculates the current-time coordination based on short-circuit analysis and applies it on site.